Cat. No.
|
|
|
|
1CJDT0
|
|
|
Parameters
|
|
|
|
|
|
|
|
|
|
Timer Description
|
|
Multi Function Timer
|
|
Asymmetric Timer
|
Modes
|
|
1)
|
Signal ON Delay
|
|
1) Asymmetric ON-OFF,
|
|
|
|
|
|
|
2)
|
Cyclic ON/OFF
|
|
2) Asymmetric OFF-ON
|
|
|
|
|
|
|
3)
|
Cyclic OFF/ON
|
|
|
|
|
|
|
|
|
|
4)
|
Signal OFF Delay
|
|
|
|
|
|
|
|
|
|
5)
|
Signal OFF/ON
|
|
|
|
|
|
|
|
|
|
6) Accumulative Delay on Signal
|
|
|
|
|
|
|
|
|
|
7)
|
Impulse ON/OFF
|
|
|
|
|
|
|
|
|
|
8)
|
Leading Edge Impulse
|
|
|
|
|
|
|
|
|
|
9)
|
Trailing Edge Impulse
|
|
|
|
|
|
|
|
|
|
10) Leading Edge Bi-stable
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Derived Modes
|
|
ON Delay, Interval
|
|
|
|
Supply Voltage (
|
|
)
|
|
|
12 - 240 VAC/DC
|
|
|
|
|
|
|
|
|
|
|
|
Supply Variation
|
|
-15% to +10% (of
|
|
)
|
|
|
|
|
|
|
|
|
|
|
|
Frequency
|
|
50/60 Hz
|
|
|
|
|
|
|
Power Consumption (Max.)
|
|
2 VA
|
|
|
|
|
|
|
Timing Range
|
|
0.1s to 100h
|
|
|
|
|
|
|
Reset Time
|
|
200 ms (Max)
|
|
|
|
|
|
|
Setting Accuracy
|
|
±
|
5% of Full scale
|
|
|
|
Repeat Accuracy
|
|
± 1%
|
|
|
|
|
|
|
|
Relay Output
|
|
1 C/O
|
|
|
|
|
|
|
Output
|
Contact Rating
|
|
8A@240VAC/5A@
|
|
|
|
|
24 VDC (Resistive)
|
|
|
|
|
|
|
|
|
|
Electrical Life
|
|
1X105
|
|
|
|
|
|
|
|
Mechanical Life
|
|
5X106
|
|
|
|
|
|
|
Utilization Category
|
AC-15
|
|
Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A
|
|
|
DC-13
|
|
Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A
|
|
|
|
|
|
|
|
|
|
Operating Temperature
|
|
|
-10°C to +60°C
|
|
|
|
Storage Temperature
|
|
-15°C to +70°C
|
|
|
|
LED Indication
|
|
Green LED
|
Power ON
|
|
Green LED
|
Power ON
|
|
Yellow LED
|
Relay ON
|
|
Amber LED
|
Relay ON
|
|
|
|
|
|
|
|
Enclosure
|
|
Flame Retardant UL94-V0
|
|
|
|
Dimension (W x H x D) (in mm)
|
|
18X85X65
|
|
|
|
|
|
|
Weight (unpacked)
|
|
70 g
|
|
|
|
|
|
|
Mounting
|
|
DIN Rail
|
|
|
|
|
|
|
Certification
|
|
|
|
RoHS Compliant
|
|
|
|
|
|
|
|
|
|
Degree of Protection
|
|
IP 20 for Terminals, IP 30 for Enclosure, IP 40 for Front side
|
|
|
EMI / EMC
|
|
|
|
|
|
|
|
|
Harmonic Current Emissions
|
IEC 61000-3-2
|
|
|
|
ESD
|
IEC 61000-4-2
|
|
|
|
Radiated Susceptibility
|
IEC 61000-4-3
|
|
|
|
Electrical Fast Transients
|
IEC 61000-4-4
|
|
|
|
Surges
|
IEC 61000-4-5
|
|
|
|
Conducted Susceptibility
|
IEC 61000-4-6
|
|
|
|
Voltage Dips & Interruptions (AC)
|
IEC 61000-4-11
|
|
|
|
Voltage Dips & Interruptions (DC)
|
IEC 61000-4-29
|
|
|
|
Conducted Emission
|
CISPR 14-1
|
|
|
|
|
|
|
Radiated Emission
|
CISPR 14-1
|
|
|
|
|
|
|
Environmental
|
|
|
|
|
|
|
|
|
Cold Heat
|
IEC 60068-2-1
|
|
|
|
Dry Heat
|
IEC 60068-2-2
|
|
|
|
Vibration
|
IEC 60068-2-6
|
|
|
|
Repetitive Shock
|
IEC 60068-2-27
|
|
|
|
Non-Repetitive Shock
|
IEC 60068-2-27
|
|
|
|