Cat. No.
|
|
|
|
|
|
V0DDTS1
|
|
|
|
Parameters
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Timer Description
|
|
|
|
|
|
|
Multi Function Digital Timer
|
|
Functions
|
|
1)
|
ON Delay
|
|
|
1)
|
ON Delay
|
|
|
|
|
|
|
|
|
2)
|
Cyclic OFF/ON
|
|
|
2)
|
Cyclic OFF/ON
|
|
|
|
|
|
|
|
|
3)
|
Cyclic ON/OFF
|
|
|
3)
|
Cyclic ON/OFF
|
|
|
|
|
|
|
|
|
4)
|
Signal ON/OFF
|
|
|
4)
|
Impulse on Energizing
|
|
|
|
|
|
|
|
|
5)
|
Signal OFF Delay
|
|
|
5)
|
Accumulative Delay on Signal
|
|
|
|
|
|
|
|
6)
|
Interval
|
|
|
6)
|
Accumulative Delay on Inverted Signal
|
|
|
|
|
|
|
|
7)
|
Signal OFF/ON
|
|
|
7)
|
Accumulative Impulse on Signal
|
|
|
|
|
|
|
|
8)
|
One Shot Output
|
|
|
8)
|
Signal ON Delay
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9) Inverted Signal ON Delay
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10) Signal OFF Delay
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
11) Impulse ON/OFF
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12) Signal OFF/ON
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
13) Leading Edge Impulse 1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
14) Leading Edge Impulse 2
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
15)
|
Trailing Edge Impulse 1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
16)
|
Trailing Edge Impulse 2
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
17) Delayed Impulse
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
18)
|
Inverted Signal ON Delay
|
Supply Voltage (
|
|
)
|
|
|
|
24 - 240 VAC/DC
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Supply Variation
|
|
-15% to +10% (of
|
|
)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Frequency
|
|
50/60 Hz
|
|
|
|
|
|
|
Power Consumption (Max.)
|
|
0.5 VA (@ 24/48 VAC), 4 VA (@ 110 to 265 VAC/DC)
|
|
|
|
|
Timing Range
|
|
0.1s to 999h
|
|
|
|
|
|
|
Reset Time
|
|
200 ms (Max.)
|
|
|
|
|
|
|
Repeat Accuracy
|
|
± 0.5%
|
|
|
|
|
|
|
|
|
|
|
Relay Output
|
|
|
|
|
|
1 C/O
|
|
|
Output
|
Contact Rating
|
|
8A @ 240 VAC / 24 VDC
|
(Resistive)
|
|
|
|
|
|
Electrical Life
|
|
1x105
|
|
|
|
|
|
|
|
Mechanical Life
|
|
2x107
|
|
|
|
|
|
|
Utilization Category
|
AC-15
|
|
Rated Voltage (Ue): 125/240 V, Rated Current (Ie): 3/1.5 A
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DC-13
|
|
Rated Voltage (Ue): 125/250 V, Rated Current (Ie): 2/0.22/0.1 A
|
|
|
|
|
|
|
|
Operating Temperature
|
|
|
|
-10° C to +55° C
|
|
|
|
|
|
|
Storage Temperature
|
|
-20° C to +65° C
|
|
|
|
|
|
|
Humidity (Non Condensing)
|
|
95% (Rh)
|
|
|
|
|
|
|
LED Indication
|
|
Red LEDRelay ON
|
|
|
|
|
|
|
Enclosure
|
|
Flame Retardant UL94-V0
|
|
|
|
|
|
|
Dimension (W x H x D) (in mm)
|
|
18X85X76
|
|
|
|
|
|
|
Weight (unpacked) Approx.
|
|
85 g
|
|
|
|
|
|
|
Mounting
|
|
DIN Rail
|
|
|
|
|
|
|
Certification
|
|
|
RoHS Compliant
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Degree of Protection
|
|
IP 20 for Terminals, IP 30 for Enclosure, IP 40 for Front side
|
|
EMI / EMC
|
|
|
|
|
|
|
|
|
|
|
|
Harmonic Current Emissions
|
IEC 61000-3-2
|
|
|
|
|
|
|
ESD
|
IEC 61000-4-2
|
|
|
|
|
|
|
Radiated Susceptibility
|
IEC 61000-4-3
|
|
|
|
|
|
|
Electrical Fast Transients
|
IEC 61000-4-4
|
|
|
|
|
|
|
Surges
|
IEC 61000-4-5
|
|
|
|
|
|
|
Conducted Susceptibility
|
IEC 61000-4-6
|
|
|
|
|
|
|
Voltage Dips & Interruptions (AC)
|
IEC 61000-4-11
|
|
|
|
|
|
|
Voltage Dips & Interruptions (DC)
|
IEC 61000-4-29
|
|
|
|
|
|
|
Conducted Emission
|
CISPR 14-1
|
|
|
|
|
|
|
Radiated Emission
|
CISPR 14-1
|
|
|
|
|
|
|
Environmental
|
|
|
|
|
|
|
|
|
|
|
|
Cold Heat
|
IEC 60068-2-1
|
|
|
|
|
|
|
Dry Heat
|
IEC 60068-2-2
|
|
|
|
|
|
|
Vibration
|
IEC 60068-2-6
|
|
|
|
|
|
|
Repetitive Shock
|
IEC 60068-2-27
|
|
|
|
|
|
|
Non-Repetitive Shock
|
IEC 60068-2-27
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|