• Auto start controller
Item Name: Auto start controller
SKU 1: ACGEN2.0
SKU 2: 0
  • Next Product

The ACGEN 2.0 is a complete auto start controller with remote start/stop for a single generating set operating in standby mode. This controller is used for automatic and manual control of generators. The test feature allows you to set various daily or weekly self tests of the generator. ACGEN2.0 module also handles OpEx feature for the control of fuel costs.
 
ACGEN2.0 FEATURES:
•Back−lit LCD graphic display with multiple information pages
•Help button for on−board instructions and multiple password access
•57 configurable alarms and protections, high accuracy TRMS measurement
•Date and time (real time clock with battery)
•3 languages available on board (English, French, Italian)
•250 engine history events log and data−logger
•System statistics: engine, alternator
•Fully programmable by keyboard & easy set up
•Engine speed measurement with magnetic pick−up or alternator frequency
•Modbus communication
 
CHARACTERISTICS
  • DC range: 8 to 32 VDC ƒ AC  supply range: 50 to 500 VAC
  • Typical standby current: 100 mADC
  • Maximum operating current: 350 mADC
  • Generator breaker relay output: 8 A ƒ 250V
  • DC outputs: 6A ƒ 28V  and 2Aƒ28V
  • Charge excitation current: 54mA @ 12VDC.
  • Voltage dropouts immunity on the power supply : 0V for 200ms
 Ports
  • 1 RS232 & 1 RS485 port for Modbus RTU communication
  • 1 CAN bus J1939 for engine communication (Scania EMS, Volvo EMS, Volvo EDC, Perkins, John Deere, Deutz, Iveco, Cummins, MTU)

 Environment

  • Operating temp.: −30˚C + 70˚C
  • Maximum humidity: 95% non-condensing.
  • Front panel protection: IP65
     
  • Dimensions and weight
  • Dimensions: 245x182x40mm
  • Panel cut-out dimensions: 220x160 mm minimum.
  • Weight: 750 g

    Homologation
  • EN61000−6−(2), (4) ƒ IEC61000−4−(2), (3), (4), (5), (6)
  • EN61000−6−(2), (4) ƒ IEC61000−4−(2), (3), (4), (5), (6)
 
PROTECTIONS
  • Low oil/ coolant level
  • Ground protection alarm & High fuel consumption
  • Start/Stop phase
  • Battery maintenance & stop failure
  • Fuel low/High leakage
  • Unexpected consumption & service
  • Refueling timeout & Remote start?stop
  • Warranty expired
  • Charger alternator failure & Test failed
  • Low/High temperature alarm (digital)
  • Battery charger alarm & emergency button
  • Feedback generator breaker & System locked
  • User alarm 1ƒ2ƒ3
  • Faulty start & Mechanical fault
  • Low/High frequency generator
  • Low/High voltage generator
  • Wrong phase sequence generator
  • Current overload & short-circuit
  • High temperature prealarm/alarm (analog)
  • Low fuel prealarm/alarm (analog)
  • Low oil pressure prealarm/alarm (analog)
  • Low/High battery voltage
  • Low/High RPM value & low autonomy


Available In Stock




Qty
-
+