• Auto transfare switch
Item Name: Auto transfare switch
SKU 1: ICGEN2.0
SKU 2: 0
  • Previous Product

 The ICGEN 2.0 is a complete auto transfer switch controller with remote start/stop for a single generating set operating in standby mode. All mains parameters are checked and in case of failure, the controller will provide a remote start signal to the generator.
When the mains reappear, the ICGEN 2.0 opens the genset breaker, switches back the
load on the mains and stops the generator a†er a programmable cooling time
 
ICGEN2.0 FEATURES:
•Back−lit LCD graphic display with multiple information pages, help button for on−board instructions, multiple
password access
•26 configurable alarms and protections, high accuracy TRMS measurement
•Date and time (real time clock with battery),
•3 languages available on board (English, French, Italian)
•System statistics: alternator and mains
•Fast & easy setup, 250 engine history events log, Modbus communication
 
CHARACTERISTICS
  • DC range: 8 to 32 VDC ƒ AC  supply range: 50 to 500 VAC
  • Typical standby current: 100 mADC
  • Maximum operating current: 350 mADC
  • Generator breaker relay output: 8 A ƒ  250V
  • Mains breaker relay output: 8 A ƒ  250V
  • DC outputs: 6 A ƒ 28V and 2 Aƒ 28V
  • Voltage dropouts immunity on the power supply : 0V for 200ms
 Ports
  • 1 RS232 & 1 RS485 port for Modbus RTU communication
 Environment
  • Operating temp.: −30˚C + 70˚C
  • Maximum humidity: 95% non-condensing.
 Dimensions and weight
  • Dimensions: 245x182x40mm
  • Panel cut-out dimensions: 220x160 mm
minimum. Weight: 750 gr
 Homologation
  • EN61000-6-(2), (4) - EN60086-2-2
  • IEC61000?4-(2), (3), (4), (5), (6)
  • IEC60086-2- (1), (2), (6) + IEC60086-2?30 - CISPR 16-1
 PROTECTIONS
  • Ground protection alarm & Test active
  • Battery maintenance, faulty mains & Test failed
  • Battery charger alarm & Emergency button
  • Feedback KG?Feedback KR, system locked & Faulty start
  • Low/High frequency generator & voltage generator
  • Wrong phase sequence generator
  • Current overload & short-circuit
  • Low/High frequency mains & voltage mains
  • Wrong phase sequence mains, user alarm 1ƒ2ƒ3
MEASUREMENTS
 Generator measurements  
  • VAC:L1ƒL2ƒL2ƒL3ƒL3?ƒL1
  • VAC:L1N-L2N-L3N
  • kVA, kW & kVAR: L1-L2-L3-Total
  • kWh
  • cos : L1-L2-L3 ƒ Frequency (Hz) ƒRun hours
   Load measurements
  • Currents: L1-L2-L3
 Mains measurements
  • VAC: L1ƒL2ƒL2ƒL3ƒL3ƒL1
  • VAC: L1N-L2N-L3N
  • kVA, kW & kVAR: L1-L2-L3-Total
  • kWh
  • cos : L1-L2-L3
  • Frequency (Hz)