TECHNICAL DATA |
|
Intended use |
Safety relay for monitoring two-hand control per EN 574 Type IIIC and protective door switches.
Module used to safely interrupt electrical circuits. |
Policies List |
EMV 2004/108/EG, Maschinen 2006/42/EG |
Standards |
EN 574 Part no. IIIC,
EN ISO 13849-1:2008,
EN 62061:2005+AC:2010,
EN 61508, Parts 1-7:2001,
EN 50178:1997,
EN 60204-1:2006+A1:2009 |
Dimensions (W x H x D) |
22.5 x 99 x 114.5 mm |
Mounting width |
22.5 mm |
Weight |
0,19 kg |
Mounting position |
As required |
Mounting |
Top-hat rail IEC/EN 60715, 35 mm |
Connection type |
M3 screw terminals |
Lifespan, mechanical [Operations] |
10 x 106 |
Terminal capacity
Solid |
1x (0.2 – 2.5)
2x (0.2 – 1) mm2 |
Terminal capacity
Flexible with ferrule |
1x (0.25 – 2.5)
2x (0.25 – 1) mm2 |
Terminal capacity
Solid or stranded |
24 - 12 AWG
|
Terminal screw
Pozidriv screwdriver |
2 Size
|
Terminal screw
Standard screwdriver |
0.6 x 3.5 mm
|
Terminal screw
Max. tightening torque |
0.6 Nm
|
Stripping length
|
7 mm
|
Material
|
Housing: polyamide PA not reinforced
Contacts: Material: silver tin oxide, gold plated (AgSnO2, 0.2 µm Au)
|
Duty factor
|
100 % DF
|
Operating conditions
Climatic environmental conditions
Climatic proofing
|
Cold to EN 60068-2-1
Dry heat to IEC 60068-2-2
Damp heat as per EN 60068-2-3
|
Operating conditions
Ambient temperature
Operation [ϑ]
|
-20 - +55 °C
|
Operating conditions
Ambient temperature
Storage [ϑ]
|
-40 - +70 °C
|
Operating conditions
Ambient temperature
Condensation
|
Non-condensing
|
Operating conditions
Atmospheric conditions
relative humidity
|
Max. 75 %
|
Operating conditions
Atmospheric conditions
Air pressure (operation)
|
795 - 1080 hPa
|
Operating conditions
Atmospheric conditions
Altitude [Above sea level]
|
2000 m
|
Power loss [P]
|
5.16 W
|